Program 22 : Incoming Call Setup
22-07 : DIL Assignment
698 Programming Aspila EX Software Manual
22-07 : DIL Assign ment
Description
Use Program 22-07 : DIL Assignment to assign the destination extension or Department Calling
Group for each DIL Incoming trunk. A DIL rings an extension directly, without any other Access
Map or Ring Group programming. If an extension has a line key, the DIL rings the line key. If the
extension does not have a line key, the DIL rings loop keys (if programmed) or one of the CALL
keys (CALL keys will always ring). Use Program 22-02 to designate a trunk as a DIL). You can
make eight DIL assignments, one for each Night Service mode:
Input Data
Conditions
Program 22-02 must be set to ‘4’ for the trunk.
Feature Cross Reference
• Direct Inward Line (DIL)
Level:
Aspila EX
IN •Available.
Trunk Port Number 001-200
Day/Night
Mode
Number of Transferring Destination Default
1-8 Extension number (Max. 8 digits)
Pilot number
No setting