Program 80 : Basic Hardware Setup for System
80-04 : Call Progress Tone Detector Setup
942 Programming Aspila EX Software Manual
80-04 : Call Progress Tone Detector Setup
Description
Use Program 80-04 : Call Progress Tone Detector Setup to define the various levels and timers
for the Call Progress Tone Detector
Input Data
Level:
Aspila EX
MF •Available.
Tone Detector Type No 1- Dial Tone for Trunk
2- Busy Tone for Trunk
3- Ring Back Tone for Trunk
4- - Reserve -
5- - Reserve -
Item No. Item Input Data
01 Detect Level 1- 0dBm…-30dBm
2- -15dBm…-45dBm
3- -30dBm…-55dBm
02 Min. detect level 0-15
detect level 0 : –15dBm(0) to –30dBm(15)
detect level 1 : –30dBm(0) to –45dBm(15)
detect level 2 : –40dBm(0) to –55dBm(15)
03 S/N ratio 0-4 (0dB…-20dB)
04 No tone time 1-255 (30+30-7650ms)
(0: No detection)
05 Pulse Count 1-255
06 ON min. time 1-255 (30+30-7650ms)
07 ON max. time 0-255 (30+30-7650ms)
(0: No detection)
08 OFF min. time 1-255 (30+30-7650ms)
09 OFF max. time 1-255 (30+30-7650ms)
(0: No detection)
10 -- Reserve -- 0-8
11 -- Reserve -- 0-8