Program 84 : Hardware Setup for VoIP
84-02 : H.225, H.245 Information Basic Setup
Aspila EX Software Manual Programming 993
84-02 : H.225, H.2 45 Information Basic Setup
Description
Use Program 84-02 : H.225, H.245 Information Basic Setup to define the data of H.225 and
H.245.
Input Data
Level:
Aspila EX
IN •Available.
Item
No.
Item Input Data Default Description
01 H.225 Alerting Timer 0-255 sec 180 sec
02 H.225 Setup Acknowledge Timer 0-255 sec 9 sec
03 H.225 Setup Timer 0-255 sec 4 sec
04 H.225 Info Ack Timer 0-255 sec 9 sec
05 H.225 Call Proceeding Timer 0-255 sec 10 sec
06 -- Not Used --
07 H.245 Master Slave Determination Timer 0-255 sec 5 sec
08 H.245 Master Slave Determination Retry
Count
0-255 sec 3 sec
09 H.245 Capability Exchange Timer 0-255 sec 5 sec
10 H.245 Logical Channel Establishment
Timer
0-255 sec 50 sec Unidirectional or bi-directional logi-
cal channel establishment timer
11 H.245 Mode Request Procedures Timer 0-255 sec 50 sec
12 H.245 Close Logical Channel Timer 0-255 sec 50 sec
13 H.245 Round Trip Delay Timer 0-255 sec 50 sec
14 H.245 Maintenance Loop 0-255 sec 50 sec
15 RAS GRQ Timer 0-255 sec 5 sec
16 GRQ Retry Count 0-255 2
17 RAS RRQ Timer 0-255 sec 5 sec
18 RRQ Retry Count 0-255 3
19 RAS URQ Timer 0-255 sec 3
20 URQ Retry Count 0-255 1
21 RAS ARQ Timer 0-255 sec 5 sec