EasyManua.ls Logo

NEC ASPILA EX - T1 Trunk Timer Setup

NEC ASPILA EX
1098 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Program 81 : Basic Hardware Setup for Trunk
81-08 : T1 Trunk Timer Setup
Aspila EX Software Manual Programming 959
81-08 : T1 Trunk Timer Setup
Description
Use Program 81-08 : T1 Trunk Timer Setup to define the various basic timers for each T1 trunk
type.
Input Data
Level:
Aspila EX
IN •Available.
Layer 3 Timer Type Number 1-5
Item No. Item Input Data Default
1 Loop - Answer Signal Detection Time 1-250 (4msec - 1020msec) 15 (60msec)
2 Ground - Answer Signal Detection Time 1-250 (4msec - 1020msec) 15 (60msec)
3 DID - Answer Signal Detection Time 1-250 (4msec - 1020msec) 15 (60msec)
4 E&M - Answer Signal Detection Time 1-250 (4msec - 1020msec) 15 (60msec)
5 OPX - Answer Signal Detection Time 1-250 (4msec - 1020msec) 15 (60msec)
6 Loop - Clear Signal Detection Time 1-255 (100msec - 25500msec) 6 (600msec)
7 Ground - Clear Signal Detection Time 1-255 (100msec - 25500msec) 6 (600msec)
8 DID - Clear Signal Detection Time 1-255 (100msec - 25500msec) 6 (600msec)
9 E&M - Clear Signal Detection Time 1-255 (100msec - 25500msec) 6 (600msec)
10 OPX - Clear Signal Detection Time 1-255 (100msec - 25500msec) 6 (600msec)
11 Loop - Ringing Signal Detection Time 1-250 (8msec - 2040msec) 10 (80msec)
12 Ground - Ringing Signal Detection Time 1-250 (8msec - 2040msec) 10 (80msec)
13 DID - Ringing Signal Detection Time 1-250 (8msec - 2040msec) 10 (80msec)
14 E&M - Ringing Signal Detection Time 1-250 (8msec - 2040msec) 10 (80msec)
15 OPX - Ringing Signal Detection Time 1-250 (8msec - 2040msec) 10 (80msec)
16 Loop - Ringing Signal Stop Detection Time 1-255 (100msec - 25500msec) 50 (3200msec)
17 Ground - Ringing Signal Stop Detection Time 1-255 (100msec - 25500msec) 50 (3200msec)
18 DID - Ringing Signal Stop Detection Time 1-255 (100msec - 25500msec) 50 (3200msec)
19 E&M - Ringing Signal Stop Detection Time 1-255 (100msec - 25500msec) 50 (3200msec)
20 OPX - Ringing Signal Stop Detection Time 1-255 (100msec - 25500msec) 50 (3200msec)
21 Loop - Loop Current Detection Time 1-250 (4msec - 1020msec) 40 (200msec)
22 Ground - Loop Current Detection Time 1-250 (4msec - 1020msec) 40 (200msec)
23 DID - Loop Current Detection Time 1-250 (4msec - 1020msec) 40 (200msec)

Table of Contents