Program 34 : Tie Line Setup
34-01 : E&M Tie Line Basic Setup
812 Programming Aspila EX Software Manual
Program 34 : Tie Line Setup
34-01 : E&M Tie Line Bas ic Setup
Description
Use Program 34-01 : E&M Tie Line Basic Setup to defines the basic settings for each E&M tie
line.
Input Data
Conditions
None
Feature Cross Reference
Tie Lines
Level:
Aspila EX
IN •Available.
Trunk port number 1-200
Item
No.
Item Input Data Default Description
Related
Program
01 DID/E&M Start Signaling
0- 2
nd
dial tone
1- Wink
2- Immediate
3- Delay
1 Set the start signaling mode for
DID and tie trunks. DID and tie
trunks can use either immediate
start or wink start signaling.
22-02
02 DID/E&M Incoming Sig-
naling Type
0- Dial Pulse
1- PB (DTMF)
0 For DID and tie trunks, use this
option to set the trunk’s signal-
ing type (Dial Pulse or DTMF)
10-09
03 E&M Dial-In Mode 0- Extension num-
ber specify
1- Use conver-
sion table
0 22-11
04 E&M Line Dial tone 0- Disable
1- Enable
1