NEC ASPILA EX - Gain Table for ARS;F-Route Access

NEC ASPILA EX
1098 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Program 44 : ARS/F-Route Setup
44-07 : Gain Table for ARS/F-Route Access
918 Programming Aspila EX Software Manual
44-07 : Gain Table for ARS/F-Route Acces s
Description
Use Program 44-07 : Gain Table for ARS/F-Route Access to set the PAD table. If an extension
dials ARS/F-Route number;
The Extension Dial Gain Table is activated, which is assigned in Program 44-05.
The Extension Dial Gain Table follows “Outgoing transmit” and “Outgoing receive” settings.
If the incoming call is transferred to another line using ARS/F-Route;
The Tandem Gain Table is activated, which is assigned in Program 44-05.
The Tandem Gain Table follows the “Incoming transmit” and “Incoming receive” settings for
incoming line, and “Outgoing transmit” and “Outgoing receive” settings for the outgoing line.
Note: For the ARS/F-Route call (in the above case), CODEC gain in Program 14-01-02 and
14-01-03 are not activated.
Input Data
Conditions
None
Feature Cross Reference
Automatic Route Selection (ARS)/F-Route
Level:
Aspila EX
IN •Available.
Gain Table Number 1-500
Item No. Item Input Data Default
01 Incoming Transmit 1-63
(-15.5 …+15.5dB)
32
02 Incoming Receive 1-63
(-15.5 …+15.5dB)
32
03 Outgoing Transmit 1-63
(-15.5 …+15.5dB)
32
04 Outgoing Receive 1-63
(-15.5 …+15.5dB)
32