Program 14 : Trunk Basic Setup
14-02 : Analogue Trunk Data Setup
Aspila EX Software Manual Programming 543
14-02 : Analogue Trunk Data Setup
Description
Use Program 14-02 : Analogue Trunk Data Setup to set the basic options for each analogue
trunk port. Refer to the chart below for a description of each option, its range and default setting.
Input Data
Level:
Aspila EX
IN •Available.
Trunk port number 1-200
Item
No.
Item Input Data Default
Related
Program
01 Signaling Type (DP/DTMF)
This option sets the signaling type for the trunk.
0- Dial Pulse (10 PPS)
1- Dial Pulse (20 PPS)
2- DTMF
2
02 Ring Detect Type
This option sets Extended Ring Detect or Immediate
Ring Defect for the trunk.
0- Normal/delayed
1- Immediately ringing
0
03 Flash Types
This option to select the flash type (open loop flash
or ground). Always set this option for open loop
flash.
0- Open Loop Flash
1- Ground
0
04 Flash For Timed Flash or Disconnect
This option lets you use Flash for Timed Flash (Pro-
gram 81-01-14) or Disconnect (Program 81-01-15).
(A user implements Flash by pressing the FLASH
key while on a trunk call.)
0- Timed flash
1- Disconnect
0 81-01-14
81-01-15
05 Dial Tone Detection for Directly Accessed
Trunks
Use this option enable/disable dial tone detection
for directly accessed trunks. If disabled, the system
outdials on the trunks without monitoring for dial
tone.
0- DTD not used
1- DTD used
1 21-01-04
06 Pause at 1st digit after line seize in manual dial
mode
0- No Pause
1- Pause
1 21-01-06