Program 22 : Incoming Call Setup
22-03 : Trunk Ring Tone Range
690 Programming Aspila EX Software Manual
22-03 : Trunk Ring Tone Range
Description
Use Program 22-03 : Trunk Ring Tone Range to select the ring tone range for the trunk. The
trunk uses a ring tone within the range selected when it rings an extension. There are four ring tones
available). Customize the Trunk Ring Tones in Program 82-01.
Input Data
Conditions
None
Level:
Aspila EX
IN •Available.
Trunk port number 1-200
Ring Tone Pattern Default Description
Related
Program
0-3
(Ring Tone pattern 1-4)
0 Use this program to select the ring tone range
for the trunk. The trunk uses a ring tone within
the range selected when it rings an extension.
There are four ring tones available.
15-02
Incoming Signal
Frequency Pattern
Type Frequency 1 Frequency 2 Modulation
Pattern 1 High
Middle
Low
1100
660
520
1400
760
660
16Hz
16Hz
16Hz
Pattern 2 High
Middle
Low
1100
660
520
1400
760
660
8Hz
8Hz
8Hz
Pattern 3 High
Middle
Low
1100
660
520
1100
660
520
Envelope
Envelope
Envelope
Pattern 4 High
Middle
Low
1100
660
520
1100
660
520
No modulation
No modulation