EasyManua.ls Logo

NEC ASPILA EX - System Options for Caller ID

NEC ASPILA EX
1098 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Program 20 : System Option Setup
20-19 : System Options for Caller ID
Aspila EX Software Manual Programming 645
20-19 : System Op tions for Caller ID
Description
Use Program 20-19 : System Options for Caller ID to define the system options for the Caller ID
feature.
Input Data
Conditions
None
Feature Cross Reference
Caller ID
Level:
Aspila EX
IN •Available.
Item
No.
Item Input Data Default
01 Caller ID Displaying Format if Displaying Digits
are more than 12 digits.
0- First 10 digits
1- Last 10 digits
0
02 Caller ID Wait Timer
When an incoming CO call is received, the sys-
tem starts the timer. It will wait the programmed
time for Caller ID information from telco before
connecting the CO call.
0-30 5
03 Caller ID Edit Mode
Edit Caller ID Enables/disables an extension’s
ability to edit the stored Caller ID information
0- off
1- on
0
04 Wait Facility IE Timer 0-64800 10

Table of Contents