Program 30 : DSS/DLS Console Setup
30-02 : DSS Console Extension Assignment
772 Programming Aspila EX Software Manual
30-02 : DSS Console Extension Assignm ent
Description
Use Program 30-02 : DSS Console Extension Assignment to identify which extensions have
DSS Consoles connected.
• You can have up to 32 different extensions with DSS Consoles. A single extension can have
up to 32 110-Button DSS Consoles (32 is the maximum allowed per system).
• Each extension in the system can have one 24-Button DLS Console (256 maximum). An
extension can have a 24-Button DLS Console in addition to 110-Button DSS Consoles.
When programming, each extension/DSS Console(p) combination is called a Console Number.
There are 32 Console Numbers (1-32). You assign Console Numbers to extensions. When entering
data, you normally make the assignment for Console Number 1 first.
Input Data
Conditions
24-button DSS consoles cannot be daisy-chained.
Feature Cross Reference
• Direct Station Selection (DSS) Console
Level:
Aspila EX
IN •Available.
110-Button DSS Console Number 01-32
The extension number for Key Telephone connected with the
DSS console
Default
(Up to 8 digits) No setting