Program 90 : Maintenance Program
90-13 : System Information Output
Aspila EX Software Manual Programming 1045
90-13 : System In formation Outpu t
Description
Use Program 90-13 : System Information Output to define the output port to be used as the sys-
tem information output. The baud rate for the COM port should be set in Program 10-21-02.
Input Data
Conditions
None
Feature Cross Reference
None
Level:
Aspila EX
IN •Available.
Item No. Item Input Data Default
01 Output Port Type
Indicate the type of connection
used for the SMDR.
0- No setting
1- COM port (NTCPU)
2- USB port (NTCPU)
3- -- Reserve –
4- CTA/CTU
0
02 Destination Extension Number
If the output port type (item 1) is
set to CTA, enter the extension
number with the CTA connection.
Extension Number
(Up to 8 digits)
No setting
03 Output Command
Dialing 1 from this program sends
the system report to the connected
device.
Dial 1 and press HOLD
(Press only HOLD key for cancel)
-