Program 10 : System Configuration Setup
10-03 : PCB Setup
Aspila EX Software Manual Programming 421
10-03 : PCB Setup
Description
Use Program 10-03 : PCB Setup to setup and confirm the Basic Configuration data for each PCB.
When changing a defined terminal type, first set the type to ‘0’ and then plug the new device in to
have the system automatically define it, alternatively redefine the type manually.
Program 10-03 allows the editing of installed units (PCB’s), you can not edit the settings if the slot
is unused, install the PCB first then edit the settings.
Note: The items highlighted in grey are read only and cannot be changed.
Input Data
For ESIU Unit
Level:
Aspila EX
IN •Available.
Physical Port Number 01-16
B-Channel 1
Item
No.
Item Input Data Default
01 Terminal Type 0- Not set
1- Keyset/DSLT
2- SLT Adapter
3- -- Not used --
4- -- Not used --
5- -- Not used --
6- PGD (Paging)
7- PGD (Tone Ringer)
8- PGD (Doorbox)
9- PGD (ACI)
10- DSS Console
11- -- Not used --
0
02 Logical Port Number 0: Not set
1: Keyset
2: SLT Adapter
3: Not used
4: Not used
5: 2DCI Adapter 1 - 32
6: PGD (Paging)
7: PGD (for Tone Ringer) 1-8
8: PGD (for Door Box) 1-8
9: PGD (for Analogue I/F) 1-96
10: DSS
11: Not used
0