Program 20 : System Option Setup
20-01 : System Options
602 Programming Aspila EX Software Manual
Program 20 : System Option Setup
20-01 : System Op tions
Description
Use Program 20-01 : System Options to set various system options.
Input Data
Level:
Aspila EX
IN •Available.
Item
No.
Item Input Data Default Description
Related
Program
01 Operator Access
Mode
0- Step
1- Circular
0 Use this program to set up priority of a
call when calling an operator telephone.
20-17
02 Text Message Mode 0- Call mode
1- Absent mode
(Busy tone)
1 Use this program to select the mode
when calling the telephone which set up
the text message.
11-11-14
15-07-08
03 DSP Sender Resource
Selection
0- Conference
1- Caller ID
2 - MFC
0
04 - Not Used -
05 DTMF Receive
Active Time
0-64800 10 For OPXs, analogue telephones and cer-
tain analogue trunks (like DISA), the
system attaches a DTMF receiver to the
port for this interval. The system
releases the receiver after the interval
expires.
25-07-01
06 Alarm Duration 0-64800 30 This interval sets the duration of the
alarm signal.
07 Callback Ring Dura-
tion Time
0-64800 15 Callback rings an extension for this
interval.
11-12-05
15-07-35
08 Trunk Queuing Call-
back Time
0-64800 15 Trunk Queuing callback rings an exten-
sion for this interval.
11-12-05
15-07-35
09 Callback/Trunk
Queuing Cancel Time
0-64800 64800 The system cancels an extension’s Call-
back or TrunkQueueing request after
this interval.
11-12-05
15-07-35
10 Trunk Guard Timer 0-64800 1 - Not Used -
Forced Account Code
Inter-digit Time
0-64800 3 Future Item - Not Yet Available
E911 Alarm Ring
Timer
0-64800
(0: 60 Sec.)
0 Future Item - Not Yet Available