Program 80 : Basic Hardware Setup for System
80-01 : Service Tone Setup
Aspila EX Software Manual Programming 931
Program 80 : Bas ic Hardware Set up for System
80-01 : Service Tone Setup
Description
Use Program 80-01 : Service Tone Setup to define up to 64 Service Tones. Each service tone is
defined by the combination of 32 Basic Tones.
Input Data
Table-1A : Basic Tone
Level:
Aspila EX
MF •Available.
Service Tone Number 01-64
Item No. Item Input Data
1 Repeat count 0-255 (0 is endless)
Unit Number 1-8
Item No. Item Input Data
2 Basic Tone No 1-33 (0=No Tone, 33=Default Time Slot)
3 Duration count 1-255 (100-25500ms)
4 Gain level (dB) 1-63 (- 15.5…+15.5)
Basic
Tone No.
Frequency (Hz)
Level
(dB)
Basic
Tone No.
Frequency (Hz) Level (dB)
1 400 - 13 17 520 / 650 -13 / -19
2 520 -13 18 650 / 780 -13 / -19
3 580 -13 19 780 / 1040 -13 / -19
4 660 -13 20 1040 -13
5 700 -13 21 - reserve - -
6 800 -13 22 - reserve - -
7 880 -13 23 - reserve - -
8 1050 -13 24 - reserve - -
9 350 / 440 -16 / -16 25 - reserve - -
10 440 / 480 -16 / -16 26 - reserve - -