Program 82 : Basic Hardware Setup for Extension
82-06 : ISDN BRI & PRI Layer 3 (S-Point) Timer Setup
974 Programming Aspila EX Software Manual
82-06 : ISDN BRI & PRI Layer 3 (S-Point) Timer Setup
Description
Use Program 82-06 : ISDN BRI & PRI Layer 3 (S-Point) Timer Setup to define the various
basic timers for layer 3 of ISDN BRI/PRI S-Point.
Input Data
Conditions
None
Level:
Aspila EX
IN •Available.
Layer 3 Timer Type Number 1-5
Item No. Item Input Data Default
1 T301 0,180-254 (sec) 180 (sec)
2 T302 1-254 (sec) 10 (sec)
3 T303 1-254 (sec) 4 (sec)
4 T304 0-254 (sec) 20 (sec)
5 T305 1-254 (sec) 30 (sec)
6 T306 0-254 (sec) 30 (sec)
7 T307 1-254 (sec) 180 (sec)
8 T308 1-254 (sec) 4 (sec)
9 T309 1-254 (sec) 90 (sec)
10 T310 0-180 (sec) 30 (sec)
11 T312 1-254 (sec) 6 (sec)
12 T313 1-254 (sec) 4 (sec)
13 T314 1-254 (sec) 4 (sec)
14 T316 (T317+1)-254 (sec) 120 (sec)
15 T317 1-(T316-1) 60 (sec)
16 T318 1-254 (sec) 4 (sec)
17 T319 1-254 (sec) 4 (sec)
18 T320 1-254 (sec) 30 (sec)
19 T321 1-254 (sec) 30 (sec)
20 T322 1-254 (sec) 4 (sec)