Program 15 : Extension Basic Setup
15-01 : Basic Extension Data Setup
560 Programming Aspila EX Software Manual
Program 15 : Extensio n Basic Setu p
15-01 : Basic Ex tension Data Setup
Description
Use Program 15-01 : Basic Extension Data Setup to define the basic settings for each extension.
Input Data
Conditions
None
Feature Cross Reference
Refer to chart above.
Level:
Aspila EX
SA •Available.
Extension Number Max. 8 digits
Item
No.
Item Input Data Default
Related
Program
01 Extension Name
Set the extension/virtual extension
name.
Up to 12 Characters 200 - EXT 200
|
499 - EXT 499
02 Outgoing Trunk Line Preference
Use this option to set the extension’s
outgoing Trunk Line Preference. If
enabled, the extension user get trunk
dial tone when they lift the handset.
The user hears trunk dial tone only if
allowed by Trunk Access Map pro-
gramming (Programs 14-07 and
15-06). Refer to the Line Preference
feature for more details.
0- Off
1- On
014-06
21-02
03 SMDR Printout
Use this option to include or exclude
the extension you are programming in
the SMDR report.
0- Do not print on SMDR report
1- Include on SMDR report
1