Program 22 : Incoming Call Setup
22-01 : System Options for Incoming Calls
686 Programming Aspila EX Software Manual
Program 22 : Incom ing Call Setup
22-01 : System Op tions for Incoming Calls
Description
Use Program 22-01 : System Options for Incoming Calls to define the system options for incom-
ing calls.
Input Data
Level:
Aspila EX
IN •Available.
Item
No.
Item Input Data Default Description
Related
Program
01 Incoming Call
Priority
0 = Intercom Call
Priority
1 = Trunk Call
Priority
1 Use this option to determine if Intercom
calls or trunk calls have answer priority
when both are ringing simultaneously.
02 Incoming Call
Ring No Answer
Alarm
0 = Disable
1 = Enable
0 If enabled, an incoming call that rings
longer than the Ring No Answer Alarm
interval (22-01-03), will change to a
unique ring cadence to indicate that the
call has been ringing too long. If dis-
abled, this will not occur.
22-01-03
22-01-04
03 Ring No Answer
Alarm Time
0-64800 (Sec.) 60 If a trunk rings a key telephone longer
than this interval, the system changes the
ring cadence. This indicates to the user
that the call has been ringing too long.
22-01-02
04 DIL No Answer
Recall Time
0-64800 (Sec.) 0 A DIL that rings its programmed destina-
tion longer than this interval diverts to the
DIL No Answer Ring Group (set in Pro-
gram 22-08).
05 - Not Used
06 DID
Ring-No-Answer
Time
0-64800 (Sec.) 20 In systems with DID Ring-No-Answer
Intercept, this interval sets the
Ring-No-Answer time. This interval is
how long a DID call rings the destination
extension before rerouting to the inter-
cept ring group.
22-12
07 DID Incoming
Ring Group no
answer timer
0-64800 (Sec.) 20
08 DID Pilot Call No
answer timer
0-64800 (Sec.) 60
09 DID to Trunk to
Trunk no answer
timer
0-64800 (Sec.) 20

Table of Contents