Program 21 : Outgoing Call Setup
21-01 : System Options for Outgoing Calls
654 Programming Aspila EX Software Manual
Program 21 : Outgoing Call Setup
21-01 : System Options for Outgoing Calls
Description
Use Program 21-01 : System Options for Outgoing Calls to set the system options for Outgoing
Call Service.
Input Data
Level:
Aspila EX
IN •Available.
Item
No.
Item Input Data Default Related Program
01 Seizure Trunk Line Mode 0- Priority route
1- Circular route
014-05
14-06
02 Intercom Interdigit Time
When placing Intercom calls, extension users
must dial each digit within this interval.
0-64800 (Sec.) 10
03 Trunk Interdigit Time (External)
The system waits for this timer to expire
before placing the call in a talk state (Call
Timer starts after timer expires, Voice Over
and Barge-In are not allowed until after timer
expires).
0-64800 (Sec.) 10 14-02-08
04 Researched time for DTD circuit 0-64800 (Sec.) 5 14-02-05
05 Dial Tone Detection Time
If dial tone detection is enabled, the system
will wait this interval for the Telco to return
dial tone. When the interval expires, the sys-
tem assumes dial tone is not present. To dis-
able this timer (and have the system wait
continuously), enter 0.
0-64800 (Sec.) 3
06 Dial pause at first digit 0-64800 (Sec.) 1
07 Toll Restriction Override Time
After dialing the Toll Restriction Override
codes, the system removes Toll Restriction
from the extension for this interval.
0-64800 (Sec.) 10 20-08-06
21-07
08 Preset dial display hold time 0-64800 (Sec.) 10
09 Ringdown Extension Timer
A Ringdown extension automatically calls its
programmed destination after this interval.
0-64800 (Sec.) 5 20-08-09
21-11
10 Dial Digits for Toll Restriction Path control 0-24 0
11 Inter-Digit Time for Toll Restriction Path
control
0-60 0