Park
Aspila EX Software Manual Features 287
Programming
•15-07-01 : Programming Function Keys
Assign a keys as a Park Orbit key (code *04 plus Park orbit number [01-64]).
•20-06-01 : Class of Service for Extensions
Assign a Class of Service (1-15) to extensions.
•20-11-19 : Class of Service Options (Hold/Transfer Service) - Normal/Extended Park
Determine whether an extension’s Class of Service should allow normal or extended Park
(0=normal, 1=extended).
•24-01-02 : System Options for Hold - Hold Recall Callback Time
A call left parked too long recalls the extension that initially parked it for this interval.
•24-01-06 : System Options for Hold - Park Hold Time
Set the Park Hold Time (0-64800 seconds). A call left parked longer than this interval will
recall the extension that initially parked it.
•24-01-07 : System Options for Hold - Extended Park Hold Time
Set the Extended Park Hold Time (0-64800 seconds). A call left parked longer than this inter-
val will recall the extension that initially parked it.
•24-03-01 : Park Group
Assign an extension to a Park Group (01-64). An extension can only pick up a call Parked by
a member of its own Park Group.