Ring Groups
Aspila EX Software Manual Features 307
Use the charts below to program the following example:
1
Trunks ring the same in the day as at night.
For this extension . . .
1
301 Trunk 1 rings Trunk 2 flashes Trunk 3 flashes
302 Trunk 1 flashes Trunk 2 rings Trunk 3 flashes
303 Trunk 1 flashes Trunk 2 flashes Trunk 3 rings
Program 22-04 : Incoming Extension Ring Group Assignment
Ring Group
1
>
123
Trunk 1 X - -
Trunk 2 - X -
Trunk 3 - - X
X = Trunk assigned to indicated Ring Group
1
Make the same 22-05 entry for all Night Service modes.
Program 22-05 : Incoming Trunk Ring Group Assignment
Ring Group
>
123
Ext. 301 1
0
1
0
1
Ext. 302
0
1
1
0
1
Ext. 303
0
1
0
1
1
1 = Extension rings
0 = Extension doesn’t ring
1
To allow extension user to answer flashing line, be sure to give
extension incoming access to the trunk in Programs 14-07 and 15-06.