Room Monitor
312 Features Aspila EX Software Manual
Programming
•11-14-01 : Service Code Setup (for Hotel) - Hotel Room Monitor
Customize the service code (770 by default) to be used for Room Monitor.
•15-07-01 : Programming Function Keys
Assign a function key as a Room Monitor key (code 39) for both the extension being moni-
tored and the extension initiating Room Monitor.
•20-06-01 : Class of Service for Extensions
Assign a Class Of Service (1-15) to an extension.
•20-13-11 : Class of Service Options (Supplementary Service) - Room Monitor, Initiating
Extension
In an extension’s Class of Service, enable (1) or disable (0) an extension’s ability to initiate
Room Monitor.
•20-13-12 : Class of Service Options (Supplementary Service) - Room Monitor, Extension
Being Monitored
In an extension’s Class of Service, enable (1) or disable (0) an extension’s ability to be monitored.
•42-03-12 : Class of Service Options (Hotel) - SLT Room Monitor
Enable (1) or disable (0) a single line telephone’s ability to use Room Monitor.
Related Features
Programmable Function Keys
Room Monitor requires uniquely programmed function keys.
Operation
You must activate Room Monitor at the extension initiating the monitor and at the
extension you want to monitor. You can only listen to one extension at a time.
Keysets:
To activate Room Monitor (at the initiating extension):
1. Do not lift handset or press SPK.
2. Press Room Monitor key (PGM 15-07 or SC 851: 39).
3. Dial number of extension you want to monitor.
You can place and answer other calls while Room Monitor is active.
To activate Room Monitor (at the extension to be monitored):
1. Go to the extension you want to monitor.
2. Do not lift handset or press SPK.
3. Press Room Monitor key (PGM 15-07 or SC 851: 39).
4. Dial the number of the extension you are at.
For example, if you are at extension 306, dial 306.
You can place and answer other calls while Room Monitor is active.
To cancel Room Monitor (at either extension):
1. Press Room Monitor key at both the initiating extension and the monitored extension.