Program 15 : Extension Basic Setup
15-07 : Programmable Function Keys
Aspila EX Software Manual Programming 579
[2] Appearance Function Level (*00 - *99) (Service Code 852)
Conditions
When a key is programmed using service code 852, that key cannot be programmed with a function
using the 851 code until the key is undefined (000). For example with a Park Key programmed by
dialing 852 + *04 must be undefined by dialing 000 before it can be programmed as a Voice Over
key by dialing 851 + 48.
Function
Number
Function Additional Data LED Indication
*00 Not Used
*01 Trunk Key Trunk Number (001-200)
*02 Trunk Group/Loop Key Trunk Group Number
(001-100)
*03 Virtual Extension Key Extension Number or Depart-
ment Group Number
*04 Park Key Park Number (01 – 64)
*05 Loop Keys 0=Incoming + Trunk Group
Number (001-100)
1=Outgoing + Trunk Group
Number (001-100)
2=Both + Trunk Group
Number (001-100)
*06 Trunk Access Via Networking Network System Number
(01-50)
*10 ACD Log – In / Log – Out Red On: Under log-on
Off: Under log-off
*11 ACD Conversation Recording Red On: Under recording
Slow Blink (Red): Pause
*12 ACD Emergency Call Emergency call
Red On: Under monitor, Override,
Standby
*13 ACD Off Duty Mode Red On: Under off duty
Slow Blink (Red): Under reservation
*14 ACD Start / End Red On: ACD operation end
*15 ACD Monitor Mode Red On: Under monitor
*16 ACD Standby Mode Red On: Standby
*17 ACD Work Time Mode Red On: Under work time
Slow Blink (Red): Under reservation
*18 ACD overflow Control ACD Group Number Red On: Enable
Slow Blink (Red): Disable