Program 81 : Basic Hardware Setup for Trunk
81-01 : COIU Initial Data Setup
Aspila EX Software Manual Programming 947
Conditions
None
Feature Cross Reference
• Central Office Calls, Placing
Telephone Programming Instructions
To enter data for Program 81-01 (COIU Initial Data Setup):
1. Enter the programming mode.
2. 81 01
3. Enter the number of the item you want to program.
4. Enter data for the item you selected + HOLD.
5. Enter data for the next item in the program.
OR
Press MSG once to enter a new item number.
OR
Press MSG until you’ve exited that series’s programming section.
22 loop disconnect detect minimum time 1-255 (8-2040mS) 50 (400ms)
23 loop disconnect detect maximum time 1-255 (8-2040mS) 80 (640ms)
24 on hook normal detect time 1-255 (8-2040mS) 3 (24ms)
25 on hook reverse detect time 1-255 (8-2040mS) 2 (16ms)
26 on hook disconnect detect time 1-255 (16-4080mS) 188 (3008ms)
27 pulse dial break time (10pps) 1-255 (4-1020mS) 8 (32ms)
28 pulse dial make time (10pps) 1-255 (4-1020mS) 4 (16ms)
29 inter-digit time (10pps) 1-255 (32-8160mS) 19 (608ms)
30 pulse dial break time (20pps) 1-255 (4-1020mS) 4 (16ms)
31 pulse dial make time (20pps) 1-255 (4-1020mS) 2 (8ms)
32 inter-digit time (20pps) 1-255 (32-8160mS) 16 (512ms)
81-01-01
Encoding Type 0: U-LAW
back
¯ select
81-01-nn
nnnnn
¬ ®
Item
No.
Item Input Data Default