EasyManua.ls Logo

NEC UNIVERGE NEAX 2000 IPS - Page 239

NEC UNIVERGE NEAX 2000 IPS
1038 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
– 215 – NWA-008844-001 Rev.5.0
91ch3002.fm
COMMAND CODE
TITLE:
STATION CLASS-1
12
ASSIGNMENT PROCEDURE:
DATA TABLE:
STATION
+
ST
++
12YY
++
DE
EXE
+
No.
(1-8 digits)
DE
Automatic/
Manual/
Dial Intercom
No. (4 digits)
Loop
Line
No.
(4 digits)
DATA
(1-8
digits)
ICI/OPR
Line No.
(4 digits)
: Initial Data
Y SETTING DATA
RELATED
COMMAND
No. MEANING DATA MEANING
00 DTMF or DP
NOTE: This data setting
is not required for
a D
term
.
1
2
3
DP
DTMF
DP/DTMF
CM45 Y=0
01 Trunk Restriction Class X Z
11
X: Day Trunk Restriction Class
Z: Night Trunk Restriction Class
Contents of Day/Night Trunk Restriction Class
1: Unrestricted (RCA)
2: Non-Restricted 1 (RCB)
3: Non-Restricted 2 (RCC)
4: Semi-Restricted 1 (RCD)
5: Semi-Restricted 2 (RCE)
6: Restricted 1 (RCF)
7: Restricted 2 (RCG)
8: Fully-Restricted (RCH)
CM60 Y=02
CM61 Y=01
CM35
Y=11
Y=51>58
Y=61>68
CM81
CM20 Y=0-3:
A043
CM90 Y=00:
F0043
02 Service Restriction Class
A, B
XX ZZ
1515
XX: Service Restriction Class A (00-15)
ZZ: Service Restriction Class B (00-15)
NOTE: The features available in each class are
programmed in CM15.
CM15
Continued on next page
Restriction of
Connection
Trunk:
CM35
Y=51>58 (OG)
Y=61>68 (IC)
Toll Restriction:
NOVEMBER/15/2006
CM12