– 774 – NWA-008844-001 Rev.5.0
91ch3008.fm
COMMAND CODE
TITLE:
ONLINE MP-FP COMMAND OUTPUT
F6
FUNCTION:
This command is used only for maintenance.
DO NOT USE this command without the assistance of a NEC engineer.
ASSIGNMENT PROCEDURE:
DATA TABLE:
ST EXE++ ++F6Y
2ND DATA
DE
1ST DATA
(2 digits) (1-8 digits)
++ DE
: Initial Data
Y 1ST DATA 2ND DATA
No. MEANING DATA MEANING DATA MEANING
2 MP-FP command out-
put setting
00 Command Code 00
FE
NONE
Command code to be output
Output all command codes
01 FP/AP Number 00
63
NONE
FP/AP number to be output
Output all FP/AP numbers
02 FPORT Number 000
254
NONE
FPORT number to be output
Output all FPORT numbers
03 IN/OUT command setting 0
1
2
3
CCC
Display both IN command/
OUT command
Display only OUT command
Display only IN command
Not displayed
Clear all the data of CMF6
Y=2
04 Specification of displayed ter-
minal
[Series 3400 software or
later]
0
1
Other than MATWorX
MATWorX
NOTE: When using the communication software, set the second data to 0.