– 779 – NWA-008844-001 Rev.5.0
91ch3008.fm
COMMAND CODE
TITLE:
SERIAL No./ID CODE/PROGRAM REVISION READ
F8
FUNCTION:
This command is used to assign the ID code to protect a copy of the Key FD and to read a program re-
vision. DO NOT USE this command without the assistance of a NEC engineer.
PRECAUTION:
None
ASSIGNMENT PROCEDURE:
DATA TABLE:
ST EXE++ ++F8Y
2ND DATA
DE
1ST DATA
(1-4 digits) (1-30 digits)
++ DE
: Initial Data
Y 1ST DATA 2ND DATA
No. MEANING DATA MEANING DATA MEANING
0 Display of Serial
number
[North America
Only]
00
01-16
MP Serial No.
Key FD Serial No.
X....X
NONE
Serial No.
(Maximum 15 digits)
X: ASCII Code
(20H-7DH)
No data
3 ID Code for Key FD
[North America
Only]
0 ID Code Entry/Display/
Cancel NOTE 1
X....X
CCC
NONE
ID Code (30 digits)
X=0-9
Cancel
No data
1 Special ID Code Entry
NOTE 2
4320
Display of remaining time
for Special ID Code
0
7200
0 minute
7200 minutes (5 days)
2 Display of Validity/Invalid-
ity for entered ID Code
0
1
2
NONE
Valid
ID Code just entered
Invalid
ID Code not entered
Continued on next page