– 843 – NWA-008844-001 Rev.5.0
91ch3009.fm
COMMAND CODE
TITLE:
CHARGING RATE ASSIGNMENT (2)
D025
FUNCTION:
This command is used to assign the charging rate per Time Block/Metering Pulse and Break Points
(BP1, BP2) for surcharge of the charging by H-method or metering pulse.
PRECAUTION:
This command is not used in North America.
ASSIGNMENT PROCEDURE:
DATA TABLE:
Charging Rate per Time Block
Charging rate RT1, RT2 and RT3 are respectively applied to each of the ranges divided by Break Point
BP1 and BP2 for surcharge as shown below.
Continued on next page
ST
EXE
++ +
+
D025
2
ND DATA
DE
1S
T DATA
(6 digits) (1-4 digits)
++
DE
: Initial Data
1ST DATA 2ND DATA REMARKS
AA B C DD
AA: H-Method number (00-15)
B : Break Point (0-2)
C : Time ID (0-7)
Day : 0
Night : 1
Midnight: 2
DD: Charging Rank (00-15)
0 -9999: Charging Rate (
φ
) per Time
Block/Metering Pulse
Call Start Call End
BP1 BP2
RT1 RT2 RT3
CMD025