NEC UNIVERGE NEAX 2000 IPS - [Cmd027] Call Charge Development Tables

NEC UNIVERGE NEAX 2000 IPS
1038 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
– 846 – NWA-008844-001 Rev.5.0
91ch3009.fm
COMMAND CODE
TITLE:
CALL CHARGE DEVELOPMENT TABLES
D027
FUNCTION:
This command is used to assign the charging method to each dialed digit on the basis of each Develop-
ment Table designated by CMD026.
PRECAUTION:
None
ASSIGNMENT PROCEDURE:
DATA TABLE:
ST
EXE++ +
+
D027
2ND DATA
DE
1ST DATA
(4 digits) (1-6 digits)
++
DE
: Initial Data
NOTE: The actual digits sent from a trunk should be assigned.
: Initial Data
NOTE: Charging will start when the number is dialed.
1ST DATA 2ND DATA
XXX Y
XXX: Development Table No. (000-511)
Y : Dialed digit (0-9, A(*), B(#))
NOTE
XXXXX Y
XXXXX: Various Data
Y : Attribute Data
Refer to the following table
VARIOUS DATA ATTRIBUTE DATA
DATA MEANING DATA MEANING
1 No charge
2 Charging is not available
0-511 Table No. for Next Development Table 3 Wait for next digit
X YY ZZ X : K-Method/H-Method=0/1
YY: Kind of charging (00-15)
ZZ : Charging Rank (00-15)
4 Charging Identification No.
0-9 Charging No. of Flat Rate assigned by
CMD004
6 With answer signal
A No answer signal NOTE
9 Send to SMDR terminal
10000 8 Charging by metering pulse
CMD027