– 385 – NWA-008844-001 Rev.5.0
91ch3004.fm
COMMAND CODE
TITLE:
MP BUILT-IN SMDR/MCI
40
MP Built-in SMDR/MCI
NOTE 1: CM40 Y=00>14 should not be assigned when using Built-in SMDR in Local Office of Cen-
tralized Billing-CCIS.
NOTE 2: This data should be set to “0” for downloading soft key information from NEAXMail AD-8/
NEAXMail IM-16 to MP.
: Initial Data
Y
PORT LOCATION NUMBER
SETTING DATA
No. MEANING DATA MEANING
00 Function 0
1
Port 0
Port 1
10
11
14
NONE
MCI
MCI and MP Built-in SMDR
Built-in SMDR NOTE 1
No data
01 Data length 0
1
Port 0
Port 1
0
1
7 bit
8 bit
02 Parity check 0
1
Port 0
Port 1
0
1
Effective
Ineffective
03 Kind of parity 0
1
Port 0
Port 1
0
1
Even parity
Odd parity
04 Stop bit 0
1
Port 0
Port 1
0
1
1-Stop bit
2-Stop bit
05 DTR signal sent to terminal 0
1
Port 0
Port 1
0
1
Low
High
06 RTS signal sent to terminal 0
1
Port 0
Port 1
0
1
Low
High
08 Data speed 0
1
Port 0
Port 1
1
2
3
4
5
NONE
1200 bps
2400 bps
4800 bps
9600 bps
19200 bps
9600 bps
13 DRS signal sent to terminal
NOTE 2
0
1
Port 0
Port 1
0
1
High
Low
CM40