– 707 – NWA-008844-001 Rev.5.0
91ch3008.fm
COMMAND CODE
TITLE:
OAI CONTROL DATA
D7
FUNCTION:
This command is used to assign the data to control the OAI facility.
PRECAUTION:
When you need to assign the port number of the PBX for OAI, on your computer, assign the number
“1024/1025/1039/60030”. Do not assign the port number which is used for the other OAI application.
Port number assignment for the PBX is required. See CM0B Y=00>98. There is no limitation for
the port number of the computer connected to the PBX.
ASSIGNMENT PROCEDURE:
DATA TABLE:
ST EXE++ ++D7Y
DATA
DE
FUNCTION DATA
(1-5 digits) (1-4 digits)
++ DE
: Initial Data
Y 1ST DATA 2ND DATA
No. MEANING DATA MEANING DATA MEANING
0 OAI Function Key num-
ber for MSF/TMF
F1032
F1047
OAI Function key number 0
OAI Function key number 15
NOTE 1
128
191
Operation Code for MSF
192
255
Operation Code for TMF
DCX Digit number of Digit Code
(X=1-3) NOTE 2
NONE No data
1 Operation Code for MSF X
XXXX
Access Code assigned by
CM20>A084
128
191
NONE
Operation Code for MSF
NOTE 3
No data
2 Digital Announcement
Trunk card number for
MSF
000
127
Message number 1XXX XXX: 000-127: Digital
Announce-
ment Trunk
card number
Continued on next page
~
~
~~
~
~
~