– 614 – NWA-008844-001 Rev.5.0
91ch3007.fm
COMMAND CODE
TITLE:
CCIS CHANNEL DATA/IP TRUNK DATA/SIP TRUNK DATA
A7
FUNCTION:
This command is used to assign the various data to each Common Channel Handler (CCH), IP Trunk
(IPT) and SIP Trunk provided.
PRECAUTION:
CCH/IPT/SIP trunk No. is assigned by CM06 Y=07.
ASSIGNMENT PROCEDURE:
DATA TABLE:
CCIS CHANNEL DATA
ST
EXE++ +
+
A7YY
DATA
DE
CCH/IPT/SIP TRUNK No. (0-7)
(1-12 digits)
++
DE
: Initial Data
Y SETTING DATA
RELATED
COMMAND
No. MEANING DATA MEANING
00 Trunk used as Common Signaling
channel
000
254
NONE
Trunk number assigned by CM07
Y=01/Y=02
No data
CM07 Y=01, 02
01 Originating Point Code (OPC) 00001
16367
NONE
Originating Point Code
No data
NOTE 1: The Originating Point Code is used to designate an originating office in the No. 7 CCIS network.
A single OPC should be assigned to IPT No. 0 and all other Virtual IPTs provided in the same of-
fice.
NOTE 2: Do not change this data while the system is operating. If you do that, the operation of D
term
IPs will
be unstable.
02 Destination Point Code (DPC) 00001
16367
NONE
Destination Point Code
No data
03 Centralized Billing Facility 0
1
3
Distant End is a Center Office
Distant End is a Local Office
Not provided