– 714 – NWA-008844-001 Rev.5.0
91ch3008.fm
COMMAND CODE
TITLE:
INITIALIZATION/CHANGEOVER OF BACKUP CPU SYSTEM
E0
FUNCTION:
This command allows the maintenance personnel to reset the system with the CAT.
PRECAUTION:
If the setting data (Month, Day and Time) is different from the current time of the system clock set by
CM02, any request to initialize the system is not accepted and “DATA ERROR” is displayed.
ASSIGNMENT PROCEDURE:
DATA TABLE:
NOTE 1: For the Data “MMDDHHmm”, enter the Month, Date, and Time (hour and minute) of the
time, as shown below.
MM: Month (01 (Jan.)-12 (Dec.))
DD : Date (01-31)
HH : Hour (00-23)
mm : Minute (00-59)
NOTE 2: After assigning the first data, “INITIAL?” is displayed. To changeover the active/stand by
MP, assign the current time while “INITIAL?” is displayed.
“HARD WARE ERROR” is displayed when there is no stand by MP for changeover.
ST EXE++ ++E0Y
DATA
DE
TYPE OF INITIALIZATION
(2/4 digits) (8 digits)
++ DE
: Initial Data
Y TYPE OF INITIALIZATION SETTING DATA
RELATED
COMMAND
No. MEANING No. MEANING DATA MEANING
2 System Initialization 2000 MP Reset MM
DD
HH
mm
Current time dis-
played on D
term
/
ATTCON
NOTE 1
To request the initial-
ization immediately.
CM02
5 Desired FP/AP Initial-
ization
00
31
FP/AP number 00
FP/AP number 31
CM02
CM05
6 Manual changeover of
Backup CPU system
(For test)
[Series 3200 R6.1
(R6.1)]
3600 Active/Stand by
changeover
Current time dis-
played on D
term
/
ATTCON
NOTE 1
NOTE 2
To request the
changeover immedi-
ately.
CM02
CM43 Y=4
CMEC Y=5
~
~
CME0