– 828 – NWA-008844-001 Rev.5.0
91ch3009.fm
COMMAND CODE
TITLE:
TIME BLOCK ASSIGNMENT (1)/
MAXIMUM NUMBER OF CALL RECORD ASSIGNMENT
D003
FUNCTION:
This command is used to determine the time block for charging by H-Method, and also used to determine
the maximum number of call records.
PRECAUTION:
(1) The amount of call record number set by CMD003>23, 24, 25, 26, 28, 29, 30 must not exceed the
following number:
Maximum number of each 1st data of CMD003 is as follows:
(2) CMD003>23, 24, 25, 26, 28, 29, 30 are effective after executing CMD102. Before executing
CMD102, be sure to print out all of the stored call records. CMD102 deletes all of the stored call
records.
See CMD102.
ASSIGNMENT PROCEDURE:
Amount of Call Records number of CMD003 1ST data 23, 24, 25, 26, 28, 29, 30
No EXPMEM on AP00 is provided EXPMEM on AP00 is provided
When CMD001>179
is set to 0
(Local Office of
Centralized Billing-CCIS/
Stand-alone)
When CMD001>179
is set to 1
(Center Office of
Centralized Billing-CCIS)
When CMD001>179
is set to 0
(Local Office of
Centralized Billing-CCIS/
Stand-alone)
When CMD001>179
is set to 1
(Center Office of
Centralized Billing-CCIS)
1600 800 27000: When CMD003>28 is set to 0
(Call Record for CIS is not provided)
26000: When CMD003>28 is set to other than 0
(Call Record for CIS is provided)
1ST DATA
No EXPMEM on AP00 is
provided
EXPMEM on AP00 is provided
23, 30 1000 1000
24, 25, 26, 29 1600 27000
28 1020 12000
ST
EXE++ +
+
D003
2ND DATA
DE
1ST DATA
(1/2 digits) (1-5 digits)
++
DE
CMD003