– 842 – NWA-008844-001 Rev.5.0
91ch3009.fm
COMMAND CODE
TITLE:
TIME BLOCK ASSIGNMENT (2)
D024
FUNCTION:
This command is used to assign the Time Block per charging rate and Break Points (BP1, BP2) for sur-
charge of the charging by K-Method.
PRECAUTION:
None
ASSIGNMENT PROCEDURE:
DATA TABLE:
Time Block TB1, TB2 and TB3 are respectively applied to each of the ranges divided by Break Point
BP1 and BP2 for surcharge as shown below.
ST
EXE++ +
+
D024
2ND DATA
DE
1ST DATA
(6 digits) (1-5 digits)
++
DE
: Initial Data
1ST DATA 2ND DATA REMARKS
AA B C DD
AA: K-Method number (00-15)
B : Break Point (0-2)
C : Time ID (0-7)
Day : 0
Night : 1
Midnight: 2
DD: Charging Rank (00-15)
0 -65535
Time Block=0.5 × Setting Data
Call Start Call End
BP1 BP2
TB1 TB2 TB3
CMD024