– 493 – NWA-008844-001 Rev.5.0
91ch3005.fm
COMMAND CODE
TITLE:
EXTERNAL KEY FUNCTION
61
FUNCTION:
This command is used to activate and specify the function of the switch closure detection circuit card
(PN-DK00 or MP) when interfaced with external keys.
PRECAUTION:
For built-in External Key Interface of MP card, assign Key number 633 (Card No. 63, circuit No. 3).
ASSIGNMENT PROCEDURE:
DATA TABLE:
ST
EXE++ +
+
61YY
DATA
DE
KEY NUMBER
(3 digits) (1-2 digits)
++
DE
: Initial Data
Y KEY NUMBER SETTING DATA
RELATED
COMMAND
No. MEANING No. MEANING DATA MEANING
00 Destination of Tenant XX Z XX: Card No. (00-63) of
PN-DK00
Z : Circuit No. (0-3)
NOTE: Card Number
corresponds to
00-63 of
CM10/
CM14>E900-
E963.
633: Built-in External
Key Interface of
MP card
00
63
Tenant 00
Tenant 63
01 Change Day/Night trunk
restriction class by external
key
0
1
Effective
Ineffective
CM12 Y=01
03 Outgoing call restriction
on Night Mode by external
key
0
1
Effective
Ineffective
CM30 Y=08
05 Day/Night Mode change
by external key
0
1
Effective
Ineffective
CM30 Y=02,
03, 04, 05,
13, 14, 26
CM76 Y=01,
02
CM58
Y=02>09
06 Even if station-to-station
call is restricted, calling
tenant is allowed to cancel
restriction by external key
0
1
Effective
Ineffective
CM63 Y=1
Continued on next page
~
~
JULY/01/2006
CM61