– 386 – NWA-008844-001 Rev.5.0
91ch3004.fm
COMMAND CODE
TITLE:
SYSTEM TIMER DATA
41
FUNCTION:
This command is used to assign the System Timer data.
PRECAUTION:
Initial Data in the DATA TABLE represent the timing for the data “NONE”.
ASSIGNMENT PROCEDURE:
DATA TABLE:
Y=0
+ 41Y + + + + +
1ST DATA
EXE
ST
DEDE
2ND DATA
(2 digits) (2 digits)
Y
1ST
DATA
MEANING
INITIAL
DATA
2ND DATA
INCREMENT
UNIT
TIMER
0
00
Attendant Recall for
Ring Transfer, Camp-
On, and unanswered
call
31.2
33.6
seconds
01 02 03 04 05 06........................13 14
2.4 seconds
0 2.4 4.8 7.2 9.6 12.0 .................... 28.8 31.2
2.4 4.8 7.2 9.6 12.0 14.4 .................... 31.2 33.6
15 16 17 18 19 ........................................ 24
9.6 seconds
28.8 38.4 48.0 57.6 67.2..................................... 115.2
38.4 48.0 57.6 67.2 76.8.....................................124.8
01
Elapsed time before
Call Forwarding-
Don’t Answer (No
Answer) for trunk
incoming call/Auto-
matic Change of Night
Service (Attendant
Overflow)/Group
Diversion/Direct-In
Termination
32
36
seconds
01 02 03 04 05 06........................29 30
4 seconds
0 4 8 12 16 20.......................112 116
4 8 12 16 20 24.......................116 120
NOTE: For the timer of the second call forwarding,
see CM41 Y=0>46.
02
Path on delay/single-
line toll restrict defeat
guard timer
1040
ms.
01 02 03 ..........................................................14
80 ms.
80 160 240 .....................................................1120
Continued on next page
~
~
~
~
~
~
~
~
~
~
~
~
~
~
~
~
~
~
~
~
~
~
~
~
NOVEMBER/15/2006
CM41