– 380 – NWA-008844-001 Rev.5.0
91ch3003.fm
COMMAND CODE
TITLE:
AMP TRUNK CONTROL
38
FUNCTION:
This command is used to define the AMP trunk control data.
PRECAUTION:
None
ASSIGNMENT PROCEDURE:
DATA TABLE:
+ 38YY + +
INCOMING/OUTGOING TRUNK ROUTE or
+
AMP PATTERN NUMBER (4 digits or 2 digits)
ST
DE
DE
++DATA (1-2 digits)
EXE
: Initial Data
Y
INCOMING/OUTGOING TRUNK
ROUTE No. /
AMP PATTERN No.
SETTING DATA
RELATED
COMMAND
DATA MEANING
00 XX ZZ
XX : Incoming trunk route No.
ZZ : Outgoing trunk route No.
00
14
15
AMP pattern number 00
AMP pattern number 14
Not use the AMP trunk
Continued on next page
~
~
CM38