– 670 – NWA-008844-001 Rev.5.0
91ch3007.fm
COMMAND CODE
TITLE:
H.323/SIP PROFILE DATA
BA
FUNCTION:
This command is used to assign the various profile data for H.323 IP Trunk/SIP Trunk.
PRECAUTION:
(1) Profile No. for control packet is assigned by CMA7 Y=71.
(2) Profile No. for voice packet is assigned by CMBB Y=03.
ASSIGNMENT PROCEDURE:
DATA TABLE:
Y=04-49
ST
EXE
++ ++
BAYY
2ND DATA
DE
(Profile No. 00-31)
(1-24 digits)
++
DE
1ST DATA
: Initial Data
Y 1ST DATA 2ND DATA
RELATED
COMMAND
No. MEANING DATA MEANING DATA MEANING
04 TOS field Precedence
for H.323 IP trunk/SIP
trunk control packet
TOS: Type of Service
00
31
Profile number
for control packet
00
07
15
PRECEDENCE0
PRECEDENCE7
PRECEDENCE0
CM35 Y=134
CMA7 Y=71
CMBA Y=10
10 DS code point (Diff-
Serv Code Point) for
H.323 IP trunk/SIP
trunk control packet
00
31
Profile number
for control packet
00
3F
NONE
DS code point
No data
CM35 Y=161
CMA7 Y=71
CMBA Y=04
NOTE 1: Set this data when the router provides DiffServ QoS, if required.
DiffServ: Differentiated Services; one type of QoS.
QoS: Quality of Service
NOTE 2: When this data is set, the TOS field Precedence set by CMBA Y=04 is ineffective.
If you want to validate the Precedence set by CMBA Y=04, set “CCC” (data clear) for CMBA
Y=10.
Continued on next page
IPT INITIAL
SIP INITIAL
~
~
~
IPT INITIAL
SIP INITIAL
~
~
JULY/01/2006
CMBA