NEC UNIVERGE NEAX 2000 IPS - [Cmd026] Route Index for Call Charge Development

NEC UNIVERGE NEAX 2000 IPS
1038 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
– 845 – NWA-008844-001 Rev.5.0
91ch3009.fm
COMMAND CODE
TITLE:
ROUTE INDEX FOR CALL CHARGE DEVELOPMENT
D026
FUNCTION:
This command is used to assign a Development Table number for each outgoing trunk route.
PRECAUTION:
Although actual charging is not determined by the PBX, it is necessary to program this command and
CMD027 to get SMDR output.
ASSIGNMENT PROCEDURE:
DATA TABLE:
For each Table Number assigned by this command, the charging method for each dialed digit is
assigned by CMD027 as shown below.
ST
EXE++ +
+
D026
2ND DATA
DE
1ST DATA
(1-2 digits) (3 digits)
++
DE
: Initial Data
1ST DATA 2ND DATA REMARKS
0-63: Outgoing Trunk Route No. 000 -511: Development Table No.
Table
No.
XXX
Route XX
Trunk Route No.
CMD026
Dialed Digits
CMD027
1
0
9
Charging Method
CMD026