– 725 – NWA-008844-001 Rev.5.0
91ch3008.fm
COMMAND CODE
TITLE:
PASSWORD
E9
FUNCTION:
This command is used to define the Password of each Password Level and the availability of Password
Service.
PRECAUTION:
(1) When programming a Password, the Password for Password Level 7 must be set. If no Password
of Password Level 7 is set, the programming of Password Service provision (CME9>9) is restricted
with the message “CODE NOT USED”. NOTE
(2) Before setting the Password, CME9>8 (Change of Password) must be set to 0 (Allowed).
(3) CME9>9 (Password Service) must be set to 0 (Provided) after programming of all Passwords are
completed.
ASSIGNMENT PROCEDURE:
DATA TABLE:
NOTE: Password Level 7 can access all commands.
+E9+ + + + +
2ND DATA
EXEST DEDE
(1/8 digits)
1ST DATA
(1 digits)
: Initial Data
1ST DATA
2ND DATA
REMARKS
DATA MEANING
0
7
Password Level 0
Password Level 7
X
XXXXXXXX
(Maximum 8 digits)
CCC
Password
Password clear
Following Passwords are not
available:
“CC...C” (All “C”)
“FF...F” (All “F”)
8 Change of Password 0
1
Allowed
Restricted
9 Password Service 0
1
Provide
No provided
~
~
~