– 503 – NWA-008844-001 Rev.5.0
91ch3005.fm
COMMAND CODE
TITLE:
LOCATION DATA ASSIGNMENT
67
FUNCTION:
This command is used to assign the location data to the location number set by CM12 Y=39/50 (Peer-
to-Peer connection by D
term
IP), CM8A Y=5000-5255: 173 (Peer-to-Peer connection via CCIS), CM0A
Y=09 (Legacy line/trunk connection via IP-PAD), CMAD Y=29 (Peer-to-Peer connection by IP-CS/
Virtual CS/ZT for WLAN).
The location number is used for administration of the group via IP network and can be assigned to each
connection type or each group which is divided according to the network traffic.
PRECAUTION:
None
ASSIGNMENT PROCEDURE:
ST
EXE++ +
+
67YY
2 ND DATA
DE
1ST DATA
(2/4 digits) (1-5 digit)
++