EasyManua.ls Logo

NEC UNIVERGE NEAX 2000 IPS - [Cm18] Station Hunting Group

NEC UNIVERGE NEAX 2000 IPS
1038 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
– 273 – NWA-008844-001 Rev.5.0
91ch3002.fm
COMMAND CODE
TITLE:
STATION HUNTING GROUP
18
FUNCTION:
This command is used to assign stations to a Station Hunting group. There are three hunt types; Station
Hunting-Terminal, Station Hunting-Circular and Station Hunting-Secretarial.
PRECAUTION:
(1) When a Station Hunting group requires a secretary station, it is necessary to assign CM18 Y=2.
(2) The maximum number of stations which can be assigned to a Station Hunting group is 60.
(3) There is no limitation to the number of Station Hunting groups.
(4) An individual station cannot be assigned to more than one Hunting group.
(5) Only one hunting system (Station Hunting-Terminal/Station Hunting-Circular/Station Hunting-
Secretarial) can be assigned to a Hunting group.
ASSIGNMENT PROCEDURE:
ST
EXE++ +
+
18Y
DATA
DE
STATION NUMBER (A)
(1-8 digits) (1-8 digits)
++
DE
CM18

Table of Contents

Other manuals for NEC UNIVERGE NEAX 2000 IPS

Related product manuals