– 410 – NWA-008844-001 Rev.5.0
91ch3004.fm
COMMAND CODE
TITLE:
SYSTEM COUNTER DATA
42
DATA TABLE:
System Counter Data
: Initial Data
KIND OF SYSTEM COUNTER SETTING DATA REMARKS
00 Number of waiting calls which will cause
attendant’s Call Waiting lamp to flash
[Large type ATTCON]
01
48
NONE
1 call
48 calls
6 calls
Number of waiting calls which will cause
attendant’s CWXX on LCD to flash
[ATTCON/DESKCON]
NOTE: XX represents the number of waiting
calls.
01 Number of stations in Line Lockout to give
MN (minor) alarm
01
99
NONE
1 station
99 stations
No “Lockout Alarm Dis-
play”
03 Number of Wake Up call/Timed Reminder
call attempts before abandonment
01
05
NONE
1 call
5 calls
5 calls
04 Maximum number of stations that are able to
set Wake Up call/Timed Reminder call at the
same time
NOTE: This command is effective up to Se-
ries 3400 software.
01
32
NONE
1 station
32 stations
10 stations
05 Number of detected faulty trunks to give MN
(minor) alarm on Attendant Console
[Australia Only]
01
99
NONE
1 trunk
99 trunks
No detection
06 Number of detected faulty trunks to give MN
(minor) alarm
[Australia Only]
01
99
NONE
1 trunk
99 trunks
No detection