– 488 – NWA-008844-001 Rev.5.0
91ch3005.fm
COMMAND CODE
TITLE:
IP ADDRESS FOR IP TRUNK/SIP TRUNK POINT-TO-MULTIPOINT
CONNECTION
5B
FUNCTION:
This command is used to assign the destination IP Address for the IP trunk/SIP trunk Point-to-Multipoint
connection.
PRECAUTION:
None
ASSIGNMENT PROCEDURE:
DATA TABLE:
ST
EXE++ +
+
5BYY
2ND DATA
DE
1ST DATA
(5 digits) (12 digits)
++
DE
: Initial Data
Y 1ST DATA 2ND DATA
No. MEANING DATA MEANING DATA MEANING
01 Destination IP Address
for IP trunk/SIP trunk
XXX ZZ XXX: 000-255
(IP Address Pattern No.)
ZZ: IP Address No. 00-07
NOTE 1
0000000
00000
2552552
55255
NONE
Destination IP Address of
opposite IP trunk/opposite
Virtual IP trunk/opposite
SIP trunk NOTE 2
No data
NOTE 1: IP Address number (00-07) is the number for specifying the IP Address of opposite office which
has plural IP Addresses, when the offices are connected with Point-to-Multipoint.
If the opposite office has plural IP Addresses, set plural IP Address numbers. If the opposite office
has only one IP Address such as 2000 IPS, set one IP Address number.
NOTE 2: Destination IP Address of opposite IP trunk/opposite Virtual IP trunk/opposite SIP trunk is the IP
Address of opposite 2000 IPS assigned by CM0B Y=00/02 or the IP Address of opposite 2400 IPX.
NOTE 3: This command should be assigned from the leading number of 1st data (IP Address pattern No. +
IP Address No.).
NOTE 4: For SIP trunk over the NAT, assign the destination IP Address of SIP card under the same NAT.
NOTE 5: For SIP trunk over the NAT, use the IP Address pattern No. assigned by CMBA Y=129.
02 Destination Base First
Port No. for Voice
Packet transmitting/
receiving for SIP trunk
[Series 3700 R12.2]
XXX ZZ XXX: 000-255
(IP Address Pattern No.)
ZZ: IP Address No. 00-07
NOTE 1
01024
65000
NONE
RTP Base Port No. for
Voice Packet transmitting/
receiving for SIP trunk
No data
NOTE 1: For SIP over the NAT, assign the destination RTP Base Port No. for Voice Packet transmitting/
receiving for SIP trunk under the same NAT.
NOTE 2: To register multiple destination, set the 2nd data opening 320 or more.
~ ~
JULY/01/2006
CM5B