– 329 – NWA-008844-001 Rev.5.0
91ch3003.fm
COMMAND CODE
TITLE:
MFC/MF-ANI TRUNK DATA
31
FUNCTION:
This command is used to assign the attribute data to MFC/MF-ANI trunk lines.
PRECAUTION:
None
ASSIGNMENT PROCEDURE:
DATA TABLE:
ST
EXE
++ ++
31Y
2ND DATA
DE
1ST DATA
(1-2 digits) (1-2 digits)
++
DE
: Initial Data
Y
1ST DATA 2ND DATA
DATA MEANING DATA MEANING
0 0 Nation code 01
02
03
04
15
NONE
Australia
UK
North America
Asia/Africa/Europe/Latin America/
Middle East/Russia
New Zealand
Nation code by Key ROM
Nation code
[For EU]
[Series 3400]
04 Austria/Belgium/Denmark/Germany/Italy/
South Africa/Spain/Sweden/Switzerland/
The Netherlands/UK/Brazil/China/Interna-
tional/Latin America/Asia
NOTE 1: Initial data of CM31 Y=0>0 depends on each nation code of the MP program.
For Australia/NZ: 01
For UK: 02
For North America: 03
For Asia/Africa/Europe/Latin America/Middle East/Russia: 04
NOTE 2: In case of EU, the initial data of CM31 Y=0>0 is same as North America (nation code 03).
Therefore, you must set the nation code to 04 by this command.
NOTE 3: A-law/µ-law setting is decided in the following order.
1. Setting of CM04 Y=10
2. Setting by Key ROM
3. Setting of SW2-1 of the MP
Continued on next page