– 611 – NWA-008844-001 Rev.5.0
91ch3006.fm
COMMAND CODE
TITLE:
EVENT OCCURRENCE NOTICE BUTTON ASSIGNMENT
9B
FUNCTION:
This command is used to provide the event occurrence notice button. When the offices with CCIS via
Virtual IPT connection are disconnected due to a fault occurrence, the link down can be notified to the
D
term
s/D
term
IPs that are connected to the offices. Also the main site and remote site are disconnected
due to a fault occurrence, the link down can be notified to the D
term
s/D
term
IPs that are connected to the
both site.
PRECAUTION:
None
ASSIGNMENT PROCEDURE:
DATA TABLE:
ST
EXE
+
++
+
9BY
DATA
DE
EVENT OCCURRENCE NOTICE
+
(1 digit)
++
DE
LINK DOWN NOTICE FOR
(4 digits)
CCIS/Remote PIM over IP
BUTTON NUMBER
Y 1ST DATA SETTING DATA
RELATED
COMMAND
No. MEANING DATA MEANING DATA MEANING
0 Link down notice
for CCIS/Remote
PIM over IP to the
Event Occurrence
Notice button
XX ZZ XX: 01-36: Event
Occurrence
Notice Button
No.
ZZ : 00: Link down
notice for CCIS
01-30: Remote
Site No. to be
notified
31: Link down
notice for SIP
[Series 3600]
0
1
To notify
Not notified
CM90 Y=00:
F1364-F1399
NOVEMBER/15/2006
CM9B