– 432 – NWA-008844-001 Rev.5.0
91ch3004.fm
COMMAND CODE
TITLE:
PERIODIC MAINTENANCE/OFFICE DATA PERIODIC COPY IN BACKUP CPU
SYSTEM/D
term
IP FIRMWARE AUTOMATIC UPDATE/OFFICE DATA COPY
43
FUNCTION:
This command is used to set the date, time and check item for periodic maintenance. The fault informa-
tion display reminds you of the time for each periodic maintenance.
[See CMEA Fault Information Display, fault kind No. 16 Page 736
]
This command is also used to set the time for regular system data backup.
PRECAUTION:
None
ASSIGNMENT PROCEDURE:
DATA TABLE:
+ 43Y + +
1ST DATA
++ +
2ND DATA
EXEST DEDE
(2 digits) (1/4/10 digits)
: Initial Data
YMEANING
1ST
DATA
MEANING 2ND DATA MEANING
2 Date and time setting
for periodic mainte-
nance
00-07 Periodic maintenance 0-
7
YYYY MM DD HH
NONE
YYYY: Year (2000-2099)
MM : Month (01-12)
DD : Day (01-31)
HH : Hour (00-23)
No data
3 Check item for peri-
odic maintenance
0
1
7
NONE
Battery check
Check item No. 1
Check item No. 7
No data
4 Time setting for office
data periodic copy
from active MP to
stand by MP in
Backup CPU system
[Series 3200 R6.1
(R6.1)]
00-03 Time setting HH MM
NONE
HH : Hour (00-23)
MM : Minute (00-59)
0200 (2:00 a.m.)
NOTE 1: Maximum of three minutes error may occur.
NOTE 2: Maximum four stating time for office data periodic copy can be set to the system. If you set two or more
starting time, set the time with fifteen minutes or more interval.
~
~