– 433 – NWA-008844-001 Rev.5.0
91ch3004.fm
COMMAND CODE
TITLE:
PERIODIC MAINTENANCE/OFFICE DATA PERIODIC COPY IN BACKUP CPU
SYSTEM/D
term
IP FIRMWARE AUTOMATIC UPDATE/OFFICE DATA COPY
43
: Initial Data
Continued on next page
YMEANING
1ST
DATA
MEANING 2ND DATA MEANING
5 Time setting for regu-
lar system data backup
00 Regular backup time HH MM
9999
NONE
HH : Hour (00-23)
MM : Minute (00-59)
No backup the office data
0300 (3:00 a.m.)
6 Time setting for
D
term
IP firmware
automatic update
[Series 3200 R6.1
(R6.1)]
00 D
term
IP firmware auto-
matic update time
YYYY MM DD HH mm
NONE
YYYY: Year (2000-2099)
MM : Month (01-12)
DD : Day (01-31)
HH : Hour (00-23)
mm : Minutes (00-59)
No data
7 Start time for copying
the office data from
the Main Site to
Remote Sites
[Series 3200 R6.2
(R6.2)]
00 Office data copy HH MM
9999
NONE
HH : Hour (00-23)
MM : Minute (00-59)
Not copy the office data
automatically
0200 (2:00 a.m.)
NOTE 1: Office data copy is executed from the low Remote Site number to high Remote Site number.
NOTE 2: The start time for office data copy may gain/loss about three minutes from the time you set.
8 Time setting for
Automatic clock
change
[Series 3600]
00 Time setting for
automatic system clock
change from standard
time to daylight-saving
time
(for change pattern 0)
MM W D
NONE
MM: Change Month (01-12)
W : Change Week (1-4/9)
First-Fourth Week
(1-4)
Final Week (9)
D : Change Day of the
week (0-6)
0: Sunday
1: Monday
2: Tuesday
3: Wednesday
4: Thursday
5: Friday
6: Saturday
Automatic clock change is
not provided
01 Time setting for auto-
matic system clock
change from daylight-
saving time to standard
time
(for change pattern 0)
JULY/01/2006
CM43

Table of Contents