– 434 – NWA-008844-001 Rev.5.0
91ch3004.fm
COMMAND CODE
TITLE:
PERIODIC MAINTENANCE/OFFICE DATA PERIODIC COPY IN BACKUP CPU
SYSTEM/D
term
IP FIRMWARE AUTOMATIC UPDATE/OFFICE DATA COPY
43
: Initial Data
Continued on next page
Y MEANING
1ST
DATA
MEANING 2ND DATA MEANING
8 Time setting for
Automatic clock
change
[Series 3600]
02 Reading of system clock
changed day from
standard time to
daylight-saving time
(for change pattern 0)
YYYY MM DD
NONE
YYYY: Year (2000-2099)
MM : Month (01-12)
DD : Date (01-31)
Automatic clock change has
not been executed
03 Reading of system clock
changed day from
daylight-saving time to
standard time
(for change pattern 0)
04 Time setting for
automatic system clock
change from standard
time to daylight-saving
time
(for change pattern 1)
MM W D
NONE
MM: Change Month (01-12)
W : Change Week (1-4/9)
First-Fourth Week
(1-4)
Final Week (9)
D : Change Day of the
week (0-6)
0: Sunday
1: Monday
2: Tuesday
3: Wednesday
4: Thursday
5: Friday
6: Saturday
Automatic clock change is
not provided
05 Time setting for
automatic system clock
change from daylight-
saving time to standard
time
(for change pattern 1)
DECEMBER/02/2005