– 330 – NWA-008844-001 Rev.5.0
91ch3003.fm
COMMAND CODE
TITLE:
MFC/MF-ANI TRUNK DATA
31
: Initial Data
Y
1ST DATA 2ND DATA
DATA MEANING DATA MEANING
1 0 MFC PAD Control to Backward Signal
[Other than North America]
0
1
2
3
4
7
–8 dBm
–10 dBm
–11.5 dBm
–9.13 dBm
Not used
MF PAD Control to incoming signal
[North America Only]
1 Sensitive Level of MFC Receiver
[Other than North America]
00
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
–26 dBm
–27 dBm
–28 dBm
–29 dBm
–30 dBm
–31 dBm
–32 dBm
–33 dBm
–34 dBm (ITU-T Standard)
–35 dBm
–36 dBm
–37 dBm
–39 dBm
–40 dBm
–41 dBm
–38 dBm
Sensitive Level of MF Receiver
[North America Only]
00
14
15
–21 dBm
–35 dBm
–36 dBm
(–1 dBm increments)
2 Number of received digits of called
number from PSTN/T1 network
NONE
01
31
No data
1 digit
31 digits
Continued on next page
~
INITIAL
INITIAL
~
~
INITIAL
~
~
CM31

Table of Contents